​30D Syringe Pump

High Pressure Applications - up to 30,000 psi (2,068 bar)

The 30D High Pressure Syringe Pump takes traditional syringe pumps to the next level of deep well core analysis. Not only does it handle exceptional low-flow stability with ease, but it gives you the ability to reach pressures of 30,000 psi​ (2,068 bar). It is ideal for high-pressure experiments requiring precision control, such as: rock core analysis for hydrocarbon recovery studies in deep-well reservoirs; reactant feed in chemical process development; and proteomics research using nanobore capillary packed columns.

 Documents

  
  
  
DoC 30D 65D 65HP.pdfDoC 30D 65D 65HP
Acid-Catalyzed Aqueous-Phase Conversion of Biomass to Fuel Precursors App Note.pdfAcid-Catalyzed Aqueous-Phase Conversion of Biomass to Fuel Precursors App NoteApplication Note
Conducting Barite Scale Formations in Oil Production Reservoirs App Note.pdfConducting Barite Scale Formations in Oil Production Reservoirs App NoteApplication Note
Conducting Batch Reactions at Relevant Geologic Carbon Sequestration Condtions App Note.pdfConducting Batch Reactions at Relevant Geologic Carbon Sequestration Condtions App NoteApplication Note
Conducting Iron Hydroxide Precipitation Reactions at High Temperature and High Pressure App Note.pdfConducting Iron Hydroxide Precipitation Reactions at High Temperature and High Pressure App NoteApplication Note
Core Analysis App Note.pdfCore Analysis App NoteApplication Note
ECBM Gravimetric Adsorption Measurements Under Realistic Conditions App Note.pdfECBM Gravimetric Adsorption Measurements Under Realistic Conditions App NoteApplication Note
Enhanced Oil Recovery EOR App Note.pdfEnhanced Oil Recovery EOR App NoteApplication Note
Exploring New Energy Concepts App Note.pdfExploring New Energy Concepts App NoteApplication Note
Nanoscale Studies of Confined and Interfacial Compressed Fluids App Note.pdfNanoscale Studies of Confined and Interfacial Compressed Fluids App NoteApplication Note
Reactive Spray Deposition App Note.pdfReactive Spray Deposition App NoteApplication Note
Pumps Overview Brochure.pdfPumps Overview BrochureBrochure
30D Syringe Pump Data sheet.pdf30D Syringe Pump Data sheetDatasheet
DSeries Controller Data Sheet V3.0.pdfDSeries Controller Data Sheet V3.0datasheet
30D Continuous Flow Systems Tech Bulletin.pdf30D Continuous Flow Systems Tech BulletinTechnical Bulletin
Analog Input Options for Syringe Pumps Tech Bulletin.pdfAnalog Input Options for Syringe Pumps Tech BulletinTechnical Bulletin
Analog Output Options for Syringe Pumps Tech Bulletin.pdfAnalog Output Options for Syringe Pumps Tech BulletinTechnical Bulletin
Constant Pressure Pump Operation for Receive Mode Tech Bulletin.pdfConstant Pressure Pump Operation for Receive Mode Tech BulletinTechnical Bulletin
Custom Software Versions for Legacy and Current Controllers Tech Bulletin.pdfCustom Software Versions for Legacy and Current Controllers Tech BulletinTechnical Bulletin
Cylinder and System Flushing Tech Bulletin.pdfCylinder and System Flushing Tech BulletinTechnical Bulletin
Diagnostics and Troubleshooting Tech Bulletin.pdfDiagnostics and Troubleshooting Tech BulletinNewTechnical Bulletin
Dispense Mode Tech Bulletin.pdfDispense Mode Tech BulletinTechnical Bulletin
D-Series and HL-Series Syringe Pump Controller Versions Tech Bulletin.pdfD-Series and HL-Series Syringe Pump Controller Versions Tech BulletinTechnical Bulletin
D-Series Quad Dual Pump Systems for Continuous Flow and Independent Operation Tech Bulletin.pdfD-Series Quad Dual Pump Systems for Continuous Flow and Independent Operation Tech BulletinNewTechnical Bulletin
Extension Cables Tech Bulletin.pdfExtension Cables Tech BulletinNewTechnical Bulletin
Field Verification Procedures Tech Bulletin.pdfField Verification Procedures Tech BulletinTechnical Bulletin
Flash Memory Upgrade for Syringe Pump Controller Tech Bulletin.pdfFlash Memory Upgrade for Syringe Pump Controller Tech BulletinTechnical Bulletin
Gradient Pumping for Pressure, Flow, and Concentration Modes Tech Bulletin.pdfGradient Pumping for Pressure, Flow, and Concentration Modes Tech BulletinNewTechnical Bulletin
High Temperature and High Accuracy Options Tech Bulletin.pdfHigh Temperature and High Accuracy Options Tech BulletinTechnical Bulletin
Installation and Setup for a Non-Isco Pressure Transducer Tech Bulletin.pdfInstallation and Setup for a Non-Isco Pressure Transducer Tech BulletinTechnical Bulletin
1 - 30Next

 Support

When you purchase instruments from Teledyne ISCO, you not only receive innovative, high quality products, you also receive excellent customer service and product support. Your initial purchase is only the beginning of Teledyne ISCO's ongoing commitment to their customers.

 Specifications

​​​​​​30D Syringe Pump

​Capacity ​30.42 mL
​Flow Range
​0.00001 to 22 mL/min
​Flow Accuracy
​± 0.5% above 69 bar and above 0.25 mL/min
​Displacement Resolution
​1.825 nL/step
​Pressure Range
10 to 30,000 psi (0.69 to 2,068.44 bar)
​Standard Pressure Accuracy
​0.2% Full Scale (at constant temperature)
Wetted Materials
​Inconel, Nitronic 50, Graphite filled, PTFE, Hastelloy C-276, Inert polymers
​Plumbing Ports
​1/4" Autoclave Engineers, Type F250C
​Operating Temperature
​5 to 40 °C Ambient
​Power Requirements
​100 VAC, 117 VAC, 234 VAC, 50/60 Hz
​Dimensions (H x W x D)
39.4 x 10.7 x 18.4" (100 x 27 x 47 cm​)
​Weight ​Pump - 80.2 lb (36.4 kg)
Controller - 6.5 lb (3.0 kg)

​For a full list of product specifications, see the datasheet.

Datasheet

 Overview

Standard Features

  • 30D pump has 1/4" F-250 fittings for secure high-pressure connections
  • Volume delivery of 0.00001 to 22 ml/min
  • Refill rate up to 29ml/min
  • Pressure accuracy 0.2% full scale
  • Displacement resolution 1.83 nL/step
  • Exclusive "Smart Key" controller. All ISCO D-series pumps use the same controller that can operate any four pump modules, either independently or together. Operating modes include:
    - Single pump independent constant flow or pressure
    - Single pump flow - or pressure - ramp programming
    - Single pump dispensing
    - Dual pump continuous constant flow or pressure
    - Dual pump concentration gradients
    - Four-pump configured systems
  • RS-232 serial interface, RS-485 2 wire serial interface, USB and Ethernet using TCP/IP for computer control or monitoring of operating parameters.
  • Redundant safety is designed in. All D-Series pumps have mechanical and electrical fail-safes, in addition to the factory default or user-set limits.
  • Corrosion resistance. Nitronic 50 - the standard material for cylinders, pistons, and caps - is an austenitic stainless steel with outstanding strength and corrosion resistance.
  • Standard seals are heavy-duty, graphite-impregnated Teflon, providing very long life under harsh operating conditions.

Applications

  • Rock core analysis for hydrocarbon recovery studies in deep-well reservoirs
  • High pressure experiments requiring precision control
  • Proteomics research using nanobore capillary packed columns

Options and Accessories

  • Drivers for LabVIEW software from National Instruments 
  • Manual refill and outlet valve kits
  • 4-20 mA output for monitoring flow rate, pressure, and volume
  • 4-20 mA input for flow rate and pressure control
  • Analog voltage output for monitoring flow rate, pressure and volume
  • Continuous flow systems with air or electric valves