​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​2103Ci Cellular CDMA Modem Module

Size (HxWxD): 2.9 x 10.5 x 7.5 in. (7.4 x 26.7 x 19 cm)
Weight: 2.0 lbs. (0.9 kg)
Enclosure: NEMA 4X, 6P (IP68)
Material: High-impact polystyrene
Power: Provided by Teledyne Isco 2191 Battery Module
Operating temperature: -4° to 140°F (-20° to 60°C)
Storage temperature: -40° to 140°F (-40° to 60°C)
Setup and data retrieval: Via PC or compatible computer with Teledyne Isco Flowlink Software

2191 Battery Module

Size (H x W x D): 6.0 x 9.6 x 7.6 in. (15 x 24 x 19 cm)
Weight (w/o batteries): 3.2 lbs. (1.4 kg)
Enclosure: NEMA 4X, 6P (IP67)
Material: High-impact polystyrene
Batteries: Two 6V alkaline lantern or lead-acid lantern
Capacity: Alkaline - 25 Ahrs; Lead Acid - 5 Ahrs

​For a full list of product specifications, see the datasheet.

Datasheet

 Overview

​2103Ci CDMA Cellular Modem Module

Wireless flow data retrieval and alarms via CDMA; 1xRTT compatible


This cellular modem module is designed to push Teledyne ISCO 2100 Series flow meter data to a remote Flowlink® database. Data can also be downloaded from the server using an internet connection. The 2103Ci modem module uses Serial Over Internet Protocol (SOIP), so a landline modem is not required.

This ability virtually eliminates the need for routine site visits, time-consuming (and potentially dangerous) confined space entry, as well as costly installation of land lines.

Pushed-data capability

The 2103Ci can automatically send data via the internet to a designated server running Teledyne ISCO Flowlink Pro software, using economical 1xRTT data transmission. The user-specified primary data transmission interval (from 5 minutes to 24 hours) can automatically change to a secondary interval when specific conditions occur at the monitoring site. An Oracle® or Microsoft® SQL database on your server is required to use this feature. Contact the factory for additional information.

Standard Features

  • Automatic alarm messaging to pagers or cell phones via SMS & server
  • Resistance to lightning damage
  • Service coverage for most of North America
  • Compatibility with Teledyne ISCO Flowlink Data Management Software, allowing sophisticated analysis, editing, graphing, reporting, and archiving.
  • Long battery life. Pre-set conditions automatically cause the modem to power up, but the user may program specific “on times” for communication, significantly extending battery life.

Applications

  • Remote data retrieval in sewer flow studies, I & I, CSO, CMOM
  • Automatic alarm notification of overflow condition

Options and Accessories

  • Magnetic mount antenna (For elevated placement to extend range and avoid signal obstruction, e.g., where module is inside a steel enclosure or steel-framed building.)
  • Flowlink software